The helical-coil, horizontal design allows low flue-gas temperatures and high-efficiency operation.
With heat transfer oils of suitable chemical composition, it can safely reach a high operating temperature such as 300°C at an operating pressure of 6 bar.
Thermal oil boilers designed so that the oil velocity inside the coil is of the order of 2,5 – 3 m/sn preserve the chemical structure and the heat-carrying capacity of the heat transfer oil.
Pressure losses on the oil side and the gas side are low. The investment cost and the energy consumption of the selected equipment are therefore lower.
Heat bridges that could be created by the lifting and insulation substructure elements on the boiler body are prevented, so heat losses are reduced to a minimum.
It can be manufactured with an open expansion tank or a closed expansion tank with a nitrogen blanket.
Insulation of the front cover and the rear wall is provided with high-temperature refractory concrete and ceramic blanket so that heat loss is kept to a minimum.
On request, design, manufacture and commissioning can be carried out together with an economizer unit.
High-quality safety equipment provides safe and stable operation.
The PLC-controlled touchscreen control panel makes operation straightforward, and remote access from mobile devices provides fast technical support anywhere in the world.
Delivered with long-life insulation that keeps heat losses to a minimum.
Manufacture in accordance with EN12952 and the PED2014/68 CE directive
Weld inspection on our boilers is carried out by non-destructive testing (NDT) within the scope and ratios set out in EN 12952-6.
Our welded fabrication is carried out by certified welders in accordance with approved WPS and WPQR. MIG-MAG and SMAW welding techniques are applied in manufacture in line with the standards.
System Components
Akkaya high-efficiency horizontal thermal oil boiler with helical coil
Firing system (automatic fuel-fed stoker, manual grate)
High-quality boiler oil inlet and outlet valve
Boiler oil inlet and outlet temperature sensor
Boiler oil inlet and outlet pressure transmitter
Boiler oil inlet and outlet pressure gauge and 3-way connection valve
Boiler oil inlet and outlet pressure switch
Boiler oil inlet and outlet thermometer
Long-life thermal oil circulation pump group, 1 duty and 1 standby, together with inlet and outlet valves, filter, compensator and check valves
Boiler oil inlet and outlet vent valve
Flue temperature sensor
Boiler leakage detection tank and accessories
Thermal oil filling pump and accessories
Deaerator tank and accessories
Expansion tank and accessories (open type or closed type with nitrogen blanket)
PLC-based touchscreen control panel with remote access
Flue
Economizer, recuperator (Optional)
| KYK-HLZ helical thermal oil boilers | KYKHLZ 10 | KYKHLZ 12.5 | KYKHLZ 25 | KYKHLZ 37.5 | KYKHLZ 50 | KYKHLZ62.5 | KYKHLZ 75 | KYKHLZ 100 | KYKHLZ 125 | KYKHLZ 150 | KYKHLZ 175 | KYKHLZ 200 | KYKHLZ 250 | KYKHLZ 375 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. heat output (kcal/h) | 100.000 | 125.000 | 250.000 | 375.000 | 500.000 | 625.000 | 750.000 | 1.000.000 | 1.250.000 | 1.500.000 | 1.750.000 | 2.000.000 | 2.500.000 | 3.750.000 |
| Length (L) (mm) | 2000 | 2000 | 2500 | 2750 | 2750 | 3400 | 3400 | 3400 | 4600 | 5600 | 5600 | 6400 | 6400 | 6400 |
| Width (W) (mm) | 1600 | 1600 | 2000 | 2000 | 2000 | 2500 | 2500 | 2500 | 2500 | 2500 | 2500 | 2500 | 2500 | 2500 |
| Height (H) (mm) | 1750 | 2000 | 2000 | 2250 | 2700 | 2250 | 2500 | 2750 | 3000 | 3250 | 3500 | 3700 | 4400 | 5900 |
| Weight (kg)* | 5500 | 6000 | 8500 | 9000 | 10500 | 14000 | 15000 | 15500 | 19500 | 23000 | 24500 | 27000 | 30000 | 35500 |